![Ronde & Schwarz 1304.0004K03 Скачать руководство пользователя страница 823](http://html1.mh-extra.com/html/ronde-and-schwarz/1304-0004k03/1304-0004k03_user-manual_1484987823.webp)
Remote Commands
R&S
®
FPL1000
823
User Manual 1178.3370.02 ─ 11
32
32-bit floating-point numbers
For I/Q data, 8 bytes per sample are returned for this format set-
ting.
64
64-bit floating-point numbers
Compared to
REAL,32
format, twice as many numbers are
returned.
Example:
FORM REAL,32
TRACe<n>[:DATA]
<Trace>,<Data>
TRACe<n>[:DATA]?
<ResultType>
This command queries current trace data and measurement results.
The data format depends on
Suffix:
<n>
.
Parameters:
<Trace>
Selects the trace to write the data to.
TRACE1 | TRACE2 | TRACE3 | TRACE4 | TRACE5 | TRACE6
<Data>
Contains the data to transfer.
Query parameters:
<ResultType>
Selects the type of result to be returned.
TRACE1 | ... | TRACE6
Returns the trace data for the corresponding trace.
For details see
LIST
Returns the results of the peak list evaluation for Spurious Emis-
sion and Spectrum Emission Mask measurements.
For SEM measurements, one peak per range is returned.
For details see
SPURious
Returns the peak list of Spurious Emission measurements.
SPECtrogram | SGRam
Returns the results of the spectrogram result display.
For details see
Return values:
<TraceData>
For more information see tables below.
Example:
TRAC A$
Transfers trace data ('+A$') to trace 1.
Example:
TRAC? TRACE3
Queries the data of trace 3.
Setting Basic Spectrum RF Measurement Parameters