Manufacturer of high quality equipment for powder coating
________________________________________________________________
55
Cleaning the check valves
Note:
Take care by dismantling the check valve, because the ball/spring
can easily be lost!
2
1
3
1
Check valve
2
Ball
3
Spring
Note:
Do not immerse the ball in solvent!
The G2 injector should be cleaned once daily as a minimum! Nor-mally,
it is sufficient to clean as described on the previous page.
The injector should be dismantled completely once a week or in the case
of heavy contamination (see also the figure in the spare parts list).