Switch on the booth
Switch on the powder coating booth according to its operating manual.
Daily start up
The daily start-up of the PROTON II Manual gun control unit takes
place by the following steps:
Select the operating mode
Select the application mode with three predefined modes (Preset mode)
or the user-defined program mode with 20 user-defined programs (Pro-
gram mode).
1. Turn on the gun control unit with the
ON
key
2. Select the corresponding application mode with key
T12
(for
Program mode) or keys
T13/T14/T15
(for Preset mode)
The predefined mode automatically set values for high voltage and
spray-ing current:
Presetting
Desired µA
Desired kV
Flat parts
100
100
Complicated parts
22
100
Overcoating
10
100
Predefined application mode (Preset mode)
Select the preset mode with the application keys
T13/T14/T15
. The
LED of the corresponding key illuminates. No program number will be
shown on the display
A5
. The air values can be individually specified
and are automatically stored in the corresponding program.
Application mode for flat parts
This application mode is suitable for the coating of simple, flat
workpieces without larger cavities.
Application mode for complicated parts
This application mode is suitable for the coating of three-
dimensional workpieces with complicated shapes (e.g. profiles).
Application mode for recoating parts already
coated
This application mode is suitable for recoating of workpieces which
are already coated.
Exiting the Preset mode
Exit the Preset mode with the keys
T10
,
T11
or
T12
. The preset values
of the Program mode used before the Preset mode are displayed by the
control unit memory.