3.  PolarCool Performance 

The following table shows estimates of the performance of the PolarCool Zone Evaporative Cooling System.  These 
values will vary depending on the particular installation and operating conditions.   

 

PolarCool 

Model

 

Drive 

Water Consumption 

Rates 

(See Note 1) 

Power Consumption 

(Voltage) 

Typical Air 

Movement Rates 

 (cubic feet per 

minute - See Note  

2) 

Cooling 

Area 

Reservoir 

(in 

Gallons) 

36” VS 

Direct 

12 gallons per hr. 

8 amps @ 115v /60hz 

11,000 

3000 ft² 

38 

 
 
Note 1:  This estimate is under 90+ degree conditions; cooler temperatures will result in less 

water usage. 

 
Note 2:  The cooling area is very dependent on the relative humidity, temperature, and the space 

being cooled. 

 
 
 

3.1 Temperature Differential Readings 

 
The temperature drop from inlet to exit is very dependent on relative humidity and temperature.  The higher the 
ambient temperature and the drier the air, the greater the drop.  A temperature drop of 10 to 20 degrees is common. 
  

 

 

 

 

4.  Controls 
 

The PolarCool Zone features a user friendly control panel interface with status indicator lights. 

Содержание PolarCool 36" VS

Страница 1: ...Manual No 4801 6404 Rev08 12 2013 PORTABLE EVAPORATIVE COOLING SYSTEM USER S MANUAL Manufactured by PO Box 140 Bremen Alabama 35033 Phone 256 287 7000 Fax 256 287 7010...

Страница 2: ...PERATION 8 7 MAINTENANCE 8 7 1 MAINTENANCE ACCESSIBILITY 8 7 2 FREQUENCY OF PAD REPLACEMENT 9 7 3 EXTENDING PAD LIFE 9 7 3 1 Algae 9 7 3 2 Scale 9 7 3 3 Dirt and Dust 9 7 3 4 Why Drain Water From The...

Страница 3: ...azardous rotating fan blade Do not place fingers arms or other appendages into the path of the blade or operate the machine without the guards in place Use Caution When Handling Sharp Metal WARNING On...

Страница 4: ...ow directed to the attention of Customer Service Manager This limited warranty is expressly in lieu of any and all representations and warranties expressed or implied including any implied warranty of...

Страница 5: ...lons 36 VS Direct 12 gallons per hr 8 amps 115v 60hz 11 000 3000 ft 38 Note 1 This estimate is under 90 degree conditions cooler temperatures will result in less water usage Note 2 The cooling area is...

Страница 6: ...ton is used to start and stop the water pump Pump ON The green indicator PUMP ON light is ON solid when the water pump is running Low Water The red indicator LOW WATER light is ON blinking when the wa...

Страница 7: ...s tripped See Figure A page 8 IF PADS ARE NEW When pads are new their slick surface will prevent the fast water absorption that will happen with older pads For this reason it is important to allow the...

Страница 8: ...or is a common way to assure fresh air Evaporative cooling will not function properly in a closed environment 6 2 Normal Operation Under normal conditions the pump should run constantly when air is be...

Страница 9: ...s too many impurities Scale formation can be prevented by using water with a pH between 6 and 9 and silica levels below 150 ppm If this is impractical scale can be minimized by increasing the drain of...

Страница 10: ...the holes in the spray bar to clear any clogged holes The spray bar end caps may be removed for easier cleaning Ensure the holes in the spray bar point upward during operation 7 4 Flushing the Reservo...

Страница 11: ...Use High Pressure Washer To Hose Down Pads 5 Drain the reservoir 6 Shut off pump and clean out strainer 7 Refill reservoir with clean water 8 Replace pads 9 Turn on the pump to run fresh water over t...

Страница 12: ...aporation Surplus water may be sucked into the fan producing a water droplet spray directly in front of the PolarCool In some cases if you stand in front of the PolarCool you may feel the water spray...

Страница 13: ...ment screw 6 To increase water level in reservoir move float arm upward Retighten arm adjustment screw 7 Replace pads Return PolarCool to operation 8 Repeat steps 1 thru 7 above as required for proper...

Страница 14: ...g Guide Problem Check Action Reference Section Swivel casters will not turn Check installation of caster hardware Hardware must be in the proper order and location Water is splashing off of pads Pads...

Страница 15: ...Manual No 4801 5035 Rev 08 12 2013 PolarCool Page 15 of 17 11 Wiring Diagram...

Страница 16: ...n Cap 0006 0001 Liquid Level Switch 3001 0050 3 Position Connector 3006 5082 2008 and newer models Low Level Switch Harness 3001 0050 2008 and later models Swiveling Caster Tire 1065 0100 Rigid Caster...

Страница 17: ...Manual No 4801 6404 Rev 08 12 2013...

Отзывы:

Похожие инструкции для PolarCool 36" VS