2-94
LEF2-300
2
Adjustment
Information
Necessary tools
General tools
No. 2 Phillips screwdriver
2.5 mm hexagonal wrench
Special tools
1000005829
TOOL,VINYL YE UV RESISTANT ST-113
Typical work time
Contents of work
Time
Front cover sensor
adjustment
15 min.
Cover That Needs to Be Removed
Right top cover
Right panel cover
Workflow
CAUTION
•
To prevent hardened ink from entering into the nozzle, refresh print head before the adjustment. Perform medium cleaning
on all print heads if 20 minutes passes.
FUNCTION
CLEANING
MEDIUM CL.
FUNCTION
CLEANING
MEDIUM CL.
AB
Front Cover Sensor Adjustment