30
2.Installation
2. Assembly and Ink Filling
G
Attach the shaft clamps to secure the shafts in place.
To ensure the media holders do not get caught in the shaft clamps, do not place the media holders too
close to the edges.
Step 3: Install the Drain Bottle
WARNING
Perform this task with all power switches left switched off.
Failure to observe this instruction may cause the machine to move suddenly,
resulting in injury.
Procedure
A
Remove the drain pad.
This pad may have soaked up discharged fluid used in the inspection when the printer was shipped.
Exercise caution to prevent this fluid from soiling your hands or the floor.
Bolt
Bolt
Hexagonal
wrench
Hexagonal
wrench