4-30
4 Adjustment
4
1
2
3
4-6 LINEAR ENCODER SETUP (Referential Time : 10min.)
[About LINEAR ENCODER SETUP]
LINEAR ENCODER SETUP is necessary for the machine to recognize the width by the software coordinates.
It is also necessary for checking whether the encoder module can read the scale correctly in the whole width.
Lower the Pinch Rollers.
Make sure to unload the media when it is set on the
machine.
Then, turn on the SUB POWER SW while pressing [ ],
[ ] and [ ] keys to enter the SERVICE MODE.
Select the [LINEAR ENCODER] menu in the SERVICE
MENU and press the [ENTER] key.
Either of the messages will appear at the completion
of the set up.
In case of SETUP error, check the followings.
[ ], [ ], [ ] + POWER ON
[ MENU ] key
SERVICE MENU
Menu
LINEAR ENCODER
SETUP COMPLETED
LINEAR ENCODER
SETUP FAILED
SERVICE MENU
LINEAR ENCODER
NOW PROCESSING..
POS: 1361.00mm
1. Dirt/Scratch on the ENCODER SCALE.
2. Dirt/Scratch on the ENCODER MODULE.
3. ENCODER SCALE is not between the
ENCODER MODULE.
4. Backlash of the CARRIAGE MOTOR GEAR
and the DRIVE GEAR.
5. Fixation between the CARRIAGE and the CARRIAGE
WIRE.
6. Bad Contact in the cables.
Содержание SP-300
Страница 128: ...2 Electrical Section 2 2 2 2 2 MAIN BOARD DIP SW DIP SW bit 1 bit 8 Always OFF ...
Страница 134: ...2 Electrical Section 2 8 2 2 3 SERVO BOARD ...
Страница 135: ...2 Electrical Section 2 9 2 ...
Страница 140: ...2 Electrical Section 2 14 2 2 4 HEATER BOARD ...
Страница 189: ...3 Replacement of Main Parts 3 42 3 9 Carry out the LINEAR ENCODER SETUP ...
Страница 203: ...4 11 4 Adjustment 4 Service Report ...
Страница 217: ...4 25 4 Adjustment 4 25 Fix the DAMPER PLATE 24 Fix the HEAD BOARD COVER Clear Cover HEAD BOARD COVER DAMPER PLATE ...