3 Replacement of Main Parts
3-11
3
5
6
7
8
[ ]
[ ] [ ]
[ENTER]
SERVICE MENU
CAP&WIPER CTRL
CAP&WIPER CTRL
CAP
CAP
UP
Remove the PUMP COVER.
PUMP COVER
Select [CAP&WIPER CTRL] > [CAP] > [UP], and press
the [ENTER] key. The capping unit moves up. Press
the [ENTER] key 3 times, because the capping unit
moves up in 3 steps.
Turn off the SUB POWER SW, and then turn off the
MAIN POWER SW.
MAIN POWER SW
Disconnect the tube(Black) of the CAP TOP from the
tube(White) of the PUMP.
Keep the JOINT TUBE for connecting the tube of the
new CAP TOP.
Make sure to replace the CAP TOP one by
one. If you disconnect the 2 tubes at the same
time, there is a danger of connecting to a
wrong tube.
JOINT TUBE