for Tubes, Cans and Drums
B0059001 / Rev. 2.3
Technical data
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
101
Pos: 83 /Schweissnaht/ Senso ren/NS9/EC9- 8x60NT10-100-S Te chnische Daten @ 0\mod_1121265929109_501.do cx @ 567 @ 2 @ 1
9.10 Eddy current sensor EC9-8x60NT10-100-S
Technical data
Application:
Round material (non-ferrous tubes)
Diameter of tube:
10 - 250 mm
Wall thickness:
Depending on material
Measuring principle:
Eddy current
Width of measuring
patch:
4 mm
Ambient temperature:
10 - 40 °C (50 – 104 °F) (operation)
Class of protection:
IP53
Weight:
5.6 kg (12.4 lbs)
Material of enclosure:
Aluminium, nickel plated
Sensor cable:
CECM18S-G
Air gap between pole
boots and tube surface
0.2 … 0.25 mm in new condition
0.1 … 0.35 mm is permissible range
The air gaps must be within the permissible
range.
If the value gets – due to wearing - outside the
permissible range, the sensor needs to be
repaired (see also chapter 10 “Maintenance”).
Air gap between sensor
element and tube surface
0.6 … 0.65 mm in new condition
0.3 … 0.75 mm is permissible range
Pos: 84 /Schweissnaht/ Senso ren/NS9/EC9- 8x60NF10-100- S Technische Da ten @ 0\mod_1129553399437_501.docx @ 823 @ 2 @ 1
9.11 Eddy current sensor EC9-8x60NF10-100-S
Technical data
Application:
Round material (non-ferrous tubes)
Diameter of tube:
10 - 250 mm
Wall thickness:
Depending on material
Measuring principle:
Eddy current (high resolution)
Width of measuring patch:
2 mm
Ambient temperature:
10 - 40 °C (50 – 104 °F) (operation)
Class of protection:
IP53
Weight:
5.6 kg (12.4 lbs.)
Material of enclosure:
Aluminum, nickel plated
Sensor cable:
CECM18S-G
Air gap between pole boots
and tube surface
0.2 … 0.25 mm in new condition
0.1 … 0.35 mm is permissible range
The air gaps must be within the permissible
range.
If the value gets – due to wearing - outside the
permissible range, the sensor needs to be
repaired (see also chapter 10 “Maintenance”).
Air gap between sensor
element and tube surface
0.6 … 0.65 mm in new condition
0.3 … 0.75 mm is permissible range