42
4 Adjustment
4
4-9 CALIBRATION
1
Calibration done in the factory is indicated on the sticker put
on the LEFT FRAME.
2
Put the 0.25 mm Standard Ceramic Pen to the TOOL
CARRIAGE and set A2 size paper on the machine.
4
Press [SETUP] key while pressing [
], [
] and [
] keys
to enter the SERVICE MODE.
And select "Calib." with [
] and [
] keys and press the
[ENTER] key.
LEFT FRAME
3
Move the TOOL CARRIAGE fully to the right end.
Turn power on and press the [SETUP] key within 1 second.