background image

INSTRUCTION MANUAL

Information, operation & installation

SIENA

Digital electronic water heater

Содержание SIENA

Страница 1: ...INSTRUCTION MANUAL Information operation installation SIENA Digital electronic water heater ...

Страница 2: ...ust the temperature 14 7 5 Lock the control panel 15 7 6 Main Menu 15 7 6 1 Settings sub menu 16 7 6 2 Energy sub menu 17 7 6 3 Equilibrium Balance sub menu 19 7 6 4 Program sub menu 19 8 Fuzzy Logic Energy Control technology 27 9 Guidance 27 10 Servicing and maintenance 27 11 Troubleshooting 28 12 Safety precautions 29 13 Rointe Product Guarantee 29 14 European Directive 32 15 Dimensions Technica...

Страница 3: ...ot suitable for pressures lower than 0 15 MPa and a flow rate of 20 litres per minute The necessary safety equipment to comply with all national legislation is available for purchase from Rointe The main features of this product are A backlit display Enamelled steel tank Low consumption due to patented Fuzzy Logic Energy Control technology 4 pre installed programmes Anti legionella function Water ...

Страница 4: ...ment before commencing the installation Failure to observe these installation instructions could invalidate the guarantee 3 3 Water supply The water supply to the cylinder should be potable water direct from a public mains water supply with any water treatment equipment functioning correctly For optimum performance the unit should be fed via a 15 mm or 22 mm diameter supply pipe direct from the ma...

Страница 5: ...see Technical Specifications on page 36 for weights The position of the cylinder should provide easy access for servicing the controls and replacing the sheathed heating element should the need arise Pipe runs should be made as short as possible and lagged to prevent heat loss To allow for servicing and repairs the product must be mounted at least 540 mm above any surface or object so that access ...

Страница 6: ...der should be fed by an uninterrupted supply pipe into the pressure reducing valve PRV Figure 2 page 7 with a maximum supply pressure of 0 9 MPa The cylinder should not be used on any system with a supply pressure below 0 15 MPa and a flow rate of less than 20 litres per minute 4 4 Temperature and pressure relief valve The temperature and pressure relief valve T P Valve is supplied Figure 2 page 7...

Страница 7: ...ximum supply pressure of 0 9 MPa 4 6 Expansion relief valve This must be installed between the pressure reducing valve and the water heating unit in accordance with Figure 2 page 7 No other valve should be fitted between this valve and the cylinder The expansion relief valve contains a non return valve 4 7 Expansion vessel A suitable expansion vessel Figure 2 page 7 with a pre charge pressure of 0...

Страница 8: ...sible at both tundish and the final point of discharge but where this is not possible or practically difficult examples of acceptable discharge arrangements are Ideally below a fixed grating and above the water seal in a trapped gully External surfaces such as car parks hard standings grassed areas etc are acceptable providing that where children play or otherwise come into contact with discharges...

Страница 9: ...er discharge pipe D2 for common temperature relief valve outlet sizes Valve outlet size diameter inches Minimum size of discharge pipe D1 mm Min size of discharge pipe D2 mm Max resistance allowed expressed as length of straight pipe no elbows bends m Resistance created by each elbow or bend m G 1 2 15 22 28 35 up to 9 up to 18 up to 27 0 8 1 0 1 4 G 3 4 22 28 35 42 up to 9 up to 18 up to 27 1 0 1...

Страница 10: ... As the actual length is 7m a 28mm diameter copper pipe will be satisfactory 5 Electrical installation WARNING This equipment and pipework must be earthed All electrical wiring must be carried out by a competent person and in accordance with the current I E E Wiring Regulations 5 1 The sheathed heating elements Two parallel 1 2kW 230v 50Hz sheathed heating elements are pre fitted to the cylinder a...

Страница 11: ...nob both the expansion relief and the temperature and pressure relief valves for a short period to remove trapped air from behind the valve seating and to check the correct function of the discharge arrangement Check all joints for leaks and rectify as necessary With the product full of water switch on the electricity supply Check that the cylinder heats the water and the thermostat operates Turn ...

Страница 12: ...ton MANUAL AUTOMATIC button Move downwards button 7 1 2 Display panel NO DESCRIPTION 1 Programming 2 Days of the week 3 Time of day 4 Temperature selected 5 Control panel locked unlocked 6 MANUAL AUTOMATIC PILOT WIRE function indicator 7 COMFORT ECO ANTI FROST mode indicator 8 Fuzzy Logic Energy Control technology indicator heating element active indicator 9 Energy consumption indicator PILOT WIRE...

Страница 13: ...en USER mode active Not available in UK Only on demand ANTI FROST mode active Control panel locked through keypad AUTOMATIC function active Control panel locked through remote 7 2 Switching on and off stand by To switch the product on please press the button on the keypad once The image to the right will appear on the display panel when the product is switched on After 5 seconds the temperature ti...

Страница 14: ...he minutes and press to confirm Finally use the and buttons to set the day 1 Monday 2 Tuesday etc and confirm by pressing the button 7 4 Adjust the temperature To change the temperature please press the or the button To decrease the temperature press the button and to increase the temperature press the button When the water temperature is lower than the set temperature on the display panel the pro...

Страница 15: ...e note that the product is locked using a remote control then it can only be unlocked using the remote control If the product is locked using a remote control and you press the keypad on the product then the following image will appear on the display panel 7 6 Main Menu The Main Menu is accessed by pressing the menu button You can navigate through the different options available on the menu by pre...

Страница 16: ...tness of the display panel in both the STAND BY and ON modes separately To change the brightness of the display panel ensure the icon is highlighted and press the button to confirm Then with the and buttons you can switch between the two modes With the and buttons you can increase or decrease the brightness as you wish The cursor indicates the intensity of the light Once you have set the required ...

Страница 17: ...s option sets the hour minutes and day of the week in your product Please refer to section 7 3 7 6 2 Main Menu Energy sub menu The Energy sub menu provides access to functions related to energy management of the product To access select the icon displayed in the Main Menu screen and press to confirm Use the and buttons to move across the different options on the sub menu to choose your function an...

Страница 18: ...active you will see the screen on the right You can choose a time period in days for this function to be active The product has a default period of 7 days To choose a time period ensure the icon is highlighted in the Energy sub menu and press the button to access Use the and buttons to choose your number of days and press to confirm ANTILEGIONAIRE S DISEASE FUNCTION PERIOD DAYS 7 Effective Power f...

Страница 19: ... The product will return to the display panel in MANUAL function with the temperature set to 55ºC 7 6 4 Main Menu Program sub menu This section explains the operational aspects of your product in its various functions and modes What are the functions of MANUAL AUTOMATIC and PILOT WIRE functions MANUAL This function allows you to change the product between the COMFORT ECO and ANTI FROST modes and t...

Страница 20: ...IC functions To change or choose the MANUAL or AUTOMATIC function ensure the icon is highlighted in the Program sub menu and press the button to confirm You can change from AUTOMATIC to MANUAL and vice versa by pressing the button again On the display panel the symbol will appear for the AUTOMATIC function and the symbol for the MANUAL function Programming options To choose a program for your prod...

Страница 21: ...RT mode temperature between 55ºC and 73ºC using the and buttons The icon and the temperature will flash Press the button to confirm STEP 2 Select ECO mode temperature ECO mode will be programmed next Select the ECO mode temperature between 40ºC and 54 5ºC The icon and the temperature will flash Press the button to confirm STEP 3 Select the Days The days of the week will start flashing on the displ...

Страница 22: ...dividual days with different programming within your program you will need to modify each day separately starting from the Main Menu again for each day days Follow Steps 1 to 4 to program multiple differing days hours temperatures 12h PRE PROGRAMS To activate a PRE PROGRAM for your product ensure that PRE PROGRAM is highlighted in the Program sub menu Press the button to confirm and the display pa...

Страница 23: ...that START PROGRAMMING is highlighted Press the button to access and the display panel will show a flashing screen You then need to follow STEPS 1 4 on pages 22 23 to modify the temperature day hours If you wish to have different days with different programming within your program you will need to modify each day separately starting from the Main Menu again for each day days Follow STEPS 1 4 on pa...

Страница 24: ...GRAM A1 A2 A3 A4 TIME DAY Mon Fri Sat Sun Mon Fri Sat Sun Mon Sun Mon Fri Sat Sun 00 00 01 00 02 00 03 00 04 00 05 00 06 00 07 00 08 00 09 00 10 00 11 00 12 00 13 00 14 00 15 00 16 00 17 00 18 00 19 00 20 00 21 00 22 00 23 00 COMFORT ECO OFF ...

Страница 25: ...elow icons displayed on the screen take you to the following functions INSERT PIN 1 2 3 4 5 6 7 8 9 0 OK CANCEL ENABLE DISABLE functions Change PIN Upper temperature limit Lower temperature limit Enable Disable functions To access the Enable Disable function ensure the icon is highlighted in the Program sub menu and press the button to access Use the and buttons to move up and down respectively to...

Страница 26: ...rogram sub menu and press the button to access Use the and buttons to decrease or increase your desired upper temperature between 55ºC to 73ºC and press the button to confirm You will then return to the USER function screen To exit press the button to go back to the main display panel or leave for 30 seconds without pressing any buttons UPPER TEMPERATURE LIMIT 65 0ºC 40 73 Lower temperature limit ...

Страница 27: ...ing element that transfer the heat to the atmosphere in the most efficient way When the icon on the display panel is replaced with the icon then the Fuzzy Logic Energy Control technology has been activated and is working 9 Guidance When a hot tap is turned on there may be a short surge of water This is quite normal with unvented systems and does not mean there is a fault When you first fill a basi...

Страница 28: ... check that the discharge to waste is unobstructed Check that each valve seals correctly when released As the valves are pre calibrated they require no further maintenance Finally when the product is full of water switch on the mains electricity supply to the product As the system heats up check again for any leaks and rectify as necessary In the event of the manual reset cut out operating isolate...

Страница 29: ...reducing valve not working 2 Expansion relief valve not seating correctly 3 Temperature and pressure relief valve not seating correctly 1 Check pressure from pressure reducing valve if greater than 0 3 MPa replace cartridge 2 Manually lift the valve once or twice to clear any debris from the seat otherwise replace valve 13 Rointe Product Guarantee In this section we hereby describe the guarantee c...

Страница 30: ...pleted to ROINTE within 90 days of installation ROINTE reserves the right to reject the guarantee service when this information has been removed or modified after the original product purchase 13 2 2 The guarantee is only applicable if the product has been installed by a competent person in accordance with this installation manual and all current regulations and codes of practice at the time of in...

Страница 31: ...llows access for our technicians should they need to gain access to the product for repair or maintenance The user client is responsible for any costs or organisation required to provide access to the products for their repair and or substitution 13 2 7 The product has been installed indoors in a frost free environment and has solely been used for the purpose of heating potable water that complies...

Страница 32: ...uct or guarantee please contact ROINTE by telephoning 0203 321 5929 for Technical Support or by email at support rointe co uk 14 European Directive WEEE 2012 19 UE Under the European Directive 2012 19 UE on Waste Electrical and Electronic Equipment WEEE the product cannot be disposed in the usual council bins and containers They must be separated to optimize the recovery and recycling of all of th...

Страница 33: ...C FUNCTIONS Anti frost Comfort ECO User mode 4 pre installed programs Manual Automatic function TFT screen with interactive visual menu Anti legionella function Temperature evolution function 24 7 programming INSTALLATION Support tripod optional Installation position Vertical Safety valve SAFETY Safety thermostat Anti legionella disinfection cycle REGULATIONS GUARANTEES 2004 108 CE Electromagnetic...

Страница 34: ...00 DIMENSIONS Diameter x height mm 470 x 777 470 x 1 297 Installed depth mm 487 487 Distance between connections mm 100 100 CHARACTERISTICS Empty weight kg 25 2 38 5 Water connections inches 1 2 1 2 Finishes White RAL 9016 tank Black RAL 9005 control panel EAN CODE 8436045913555 8436045913135 ...

Страница 35: ...ord CUSTOMER DETAILS NAME ADDRESS TEL No INSTALLER DETAILS COMPANY NAME DATE ADDRESS TEL No INSTALLER NAME REGISTRATION No COMMISSIONING ENGINEER IF DIFFERENT COMPANY NAME DATE ADDRESS TEL No INSTALLER NAME REGISTRATION No CYLINDER DETAILS MODEL CAPACITY litres SERIAL No ...

Страница 36: ...opriate Service Interval Record below SERVICE 1 DATE SERVICE 2 DATE SERVICE ENGINEER SERVICE ENGINEER TEL NO TEL NO REGISTRATION NO REGISTRATION NO SIGNATURE SIGNATURE SERVICE 3 DATE SERVICE 4 DATE SERVICE ENGINEER SERVICE ENGINEER TEL NO TEL NO REGISTRATION NO REGISTRATION NO SIGNATURE SIGNATURE SERVICE 5 DATE SERVICE 6 DATE SERVICE ENGINEER SERVICE ENGINEER TEL NO TEL NO REGISTRATION NO REGISTRA...

Страница 37: ...e dirección postal INDUSTRIAS ROYAL TERMIC S L C E Parcela 43 30140 Santomera Murcia CERTIFICADO DE GARANTÍA REFERENCIA Nº SERIE FECHA DE COMPRA USUARIO DOMICILIO POBLACIÓN C P PROVINCIA PAÍS TELÉFONO CORREO ELECTRÓNICO SELLO DEL ESTABLECIMIENTO VENDEDOR NOTA Este certificado de garantía debe estar totalmente cumplimentado para tener derecho a la garantía no debe faltar la fecha de compra ni el se...

Страница 38: ......

Страница 39: ...water heater Thank you for choosing Rointe We hope you enjoy your product If you require further assistance or information please contact our Technical Service Department by telephoning 0203 321 5929 or email support rointe co uk ...

Страница 40: ...ROINTE UK Catalyst House 720 Centennial Court Centennial Park Elstree Herts WD6 3SY T 0203 321 5928 F 0208 953 5861 Technical Support T 0203 321 5929 E support rointe co uk www rointe co uk MSTUK18V1 ...

Отзывы: