background image

HP-160L / HP-200PP / HP-250PP

© 

Röhr

6

© 

Röhr

If you fail to fully understand this manual you should contact the suppliers or another 

professional for assistance.

1. 

Safety cut out - 

the welding machine has a safety circuit to protect against excess power, 

current or heat. This circuit will cause the welding machine to cut out automatically if 

activated. The fans will continue to cool the unit.

2. 

Machine air flow - 

the internal fan requires a free flow of air. Ensure the intake is not 

blocked or covered.

3. 

Do not overload - 

overloaded input current will impair the performance and may seriously 

damage the machine.

4. 

Grounding -

 the welding machine must be grounded by means of the grounding connector 

at the rear of the machine, fitted to ground as per the required standard.

5. 

Cleaning -

 before cleaning, the power must be turned off and disconnected from the 

mains. All cleaning should be carried out by a qualified professional. Remove dust using low 
pressure compressed air to avoid damage to fragile components inside the machine.

Electric shock - may lead to death.

•  An isolator switch is recommended when using the machine.
•  It is dangerous to touch the electrical components.
•  Wear welding gloves, ear, eye, face protection and clothing / ensure others nearby are 

protected.

•  Use suitable protective equipment or curtain to protect any on-lookers and warn all 

onlookers about the possible risk to their eyes.

•  Make sure you are well insulated from the ground.
•  Make sure you are in a safe and secure position.
•  Gas may be harmful to your health, do not inhale the gas, use an extractor.
•  Welding sparks may cause fire, make sure the welding area is fire safe.

Arc radiation can be harmful to your eyes and can burn your skin.

Health and Safety

Warning

 - Risk of injury. Pay 

special attention

Caution

 - Be aware of potential 

risks / hazards

Содержание HP-160L

Страница 1: ...lly Keep this manual in a safe place review it frequently and ensure that all users have read it to ensure safe operation Ce manuel fournit des informations de sécurité importantes et des instructions concernant la configuration de votre chargeur de batterie Afin de minimiser les risques il est important de lire attentivement ce manuel Conservez ce manuel dans un endroit sûr relisez le fréquemment...

Страница 2: ...06 Health and Safety 07 Health and Safety Technical Data 08 Troubleshooting 09 CE Declaration of Conformity Sommaire 02 Sommaire 10 Guide de Démarrage Rapide Installation 11 Guide de Démarrage Rapide Panneau de configuration 12 Guide de Démarrage Rapide Soudage 13 Sécurité 14 Sécurité Données Techniques 15 Dépannage 16 Certificat de Conformité CE ...

Страница 3: ...ure that every part of the gas supply is tightly connected Poor connections will allow gas to escape air could get into the system Use a regulating valve 3 Ground the unit by using the ground connecting screw at the back of the machine and connect to a grounded metal point free from the weld surface 4 MMA welding ensure that the cable of the Electrode Holder is securely attached to the negative te...

Страница 4: ...itch 4 Amp Output Dial Quick Start Guide Control Panels HP 160L Control Panel 1 Power Switch 2 Pulse Function Up Low frequency pulse Middle High Frequency pulse Down Normal without pulse 3 MMA TIG Function Switch 4 Gas Time Delay Dial 5 Amperes Current Dial HP 200PP HP 250PP Control Panel ...

Страница 5: ...will diminish and you can now weld 7 When welding is complete argon will continue to flow for several seconds The torch should be kept safe until the arc is extinguished TIG Welding Manual Metal Arc welding uses an electrode stick to create a contact between the material to be welded This is held in place with the stick clamp 1 Attach the earth clamp to a conductive connected part of the weld surf...

Страница 6: ...st be turned off and disconnected from the mains All cleaning should be carried out by a qualified professional Remove dust using low pressure compressed air to avoid damage to fragile components inside the machine Electric shock may lead to death An isolator switch is recommended when using the machine It is dangerous to touch the electrical components Wear welding gloves ear eye face protection ...

Страница 7: ...cted by a qualified professional 3 Do not use the machine in an environment where the air is polluted with conductive dust Health and Safety HP 160L HP 200PP HP 250PP Power Input AC 230V 15 AC 230V 15 AC 230V 15 Power Phase Single Phase Single Phase Single Phase Frequency HZ 50 60 50 60 50 60 Rated Input Current A 24 32 34 No load V 56 56 56 Output Current A 20 160 20 200 20 250 Rated Working V 16...

Страница 8: ... a taper If the tungsten electrode is not ground it will be difficult to strike arc or the arc may be unstable When MMA welding there is too much weld Ensure that the current used is not too high for the thickness of the welding rod There is no power to the unit no response from the unit Ensure that the electric cable is in good condition and connected correctly Faulty cables must not be used they...

Страница 9: ...ication code HP 160NL HP 200PP WSME 200 Conforms to the following directives and standards LVD 2014 35 EU Low Voltage Directive EMC 2014 30 EU Electromagnetic Compatibility Directive And Complies with the provisions of the following standards EN60974 1 2012 EN 60974 10 2014 EN55011 2009 A1 2010 EN 61000 3 11 2000 EN 61000 3 12 2011 Notified body I S E T SRL The technical documentation is kept by U...

Страница 10: ...tent au gaz de s échapper de l air pourrait pénétrer dans le système Utilisez une vanne de régulation 3 Mettez l unité à la terre en utilisant la vis de mise à la terre située à l arrière de la machine et connectez la à un point métallique mis à la terre en dehors de la surface de soudure 4 Soudage MMA assurez vous que le câble du porte électrode soit bien fixé à la borne négative et fixez le dans...

Страница 11: ...tie amp Guide de Démarrage Rapide Panneau de Panneau de configuration HP 160L 1 Interrupteur 2 Fonction d impulsion En Haut impulsion basse fréquence Milieu impulsion haute fréquence En Bas Normal sans impulsion 3 Commutateur de fonction MMA TIG 4 Cadran de temps de gaz 5 Ampères actuels Panneau de configuration HP 200PP HP 250PP ...

Страница 12: ...e l impact diminuera et vous pourrez maintenant souder 7 Lorsque le soudage est terminé l argon continuera à couler pendant plusieurs secondes La torche doit être gardée en sécurité jusqu à l extinction de l arc Soudage TIG Le soudage manuel à l arc des métaux utilise un bâtonnet d électrode pour créer un contact entre le matériau à souder Ceci est maintenu en place avec la pince 1 Fixez la pince ...

Страница 13: ... nettoyage doit être effectué par un professionnel qualifié Éliminez la poussière en utilisant de l air comprimé à basse pression afin d éviter d endommager les composants fragiles à l intérieur de la machine Choc électrique peut entraîner la mort Il est recommandé d utiliser un sectionneur lors de l utilisation de la machine Il est dangereux de toucher les composants électriques Porter des gants ...

Страница 14: ...fessionnel qualifié 3 N utilisez pas la machine dans un environnement où l air est pollué par des poussières conductrices Sécurité HP 160L HP 200PP HP 250PP Entrée de puissance AC 230V 15 AC 230V 15 AC 230V 15 Phase de puissance Monophasé Monophasé Monophasé Fréquence Hz 50 60 50 60 50 60 Courant d entrée nominal A 24 32 34 Sans Charge V 56 56 56 Courant de sortie A 20 160 20 200 20 250 Travail év...

Страница 15: ... qu elle soit effilée Si l électrode en tungstène n est pas mise à la masse il sera difficile de déclencher un arc ou celui ci risque d être instable Lors du soudage MMA il y a trop de soudure Assurez vous que le courant utilisé n est pas trop élevé pour l épaisseur de la baguette de soudage L unité n est pas alimentée aucune réponse de l unité Assurez vous que le câble électrique soit en bon état...

Страница 16: ...d identification HP 160NL HP 200PP WSME 200 Se conforme aux directives et normes suivantes Directive basse tension LVD 2014 35 EU Directive sur la compatibilité électromagnétique EMC 2014 30 UE Et se conforme aux dispositions des normes suivantes EN60974 1 2012 EN 60974 10 2014 EN55011 2009 A1 2010 EN 61000 3 11 2000 EN 61000 3 12 2011 Organisme notifié I S E T SRL La documentation technique est c...