7 | Maintenance
40 / 48
DURO-A RC
7.2
Maintenance Interval
The regular maintenance work is described in the following:
Activity
Interval
Lubricating Conical Lubricating
Nipples [
Approx. every 20 hrs.
depending on conditions of use and
use of coolant after 8 hrs.
or at the latest after 10,000 clamping
cycles.
.
With each jaw replacement or at the
latest after 2,500 clamping cycles.
Checking the Device for Correct
Operation [
After 30,000 clamping cycles or after
3 months depending on the conditions
of use.
Visually inspect wear parts.
Weekly
Checking the Tightness of Screw
Connections [
Weekly
Visually inspect jaw screws.
Weekly
Replace jaw screws.
Annually
Inspection of the Power Chuck
[
Annually
7.3
Maintenance Work
CAUTION
Skin irritations due to contact with lubricants.
Lubricants may cause irritations in the event of contact with the skin.
Ø
When handling the
power chuck
, wear safety goggles, long
work clothes and gloves.
Ø
Avoid skin contact with lubricants.