BD93E11GWL-EVK-001 (Stand-Alone)
BD93E11GWL-EVK-001
Type-C Cable
Type-C Port
Laptop PC
Existing system board
Up to 20V@5A
Current
Probe
USB-B
port
The observed current depends on the existing system board connected to
a VSNK terminal on the EVK. The contracted current is the maximum
current capability of a source and it doesn't means the consuming current
by a sink (It is equal to both the EVK and a load).
A 5A cable is required if
an existing system board
consumes over 3A.
USB communication is
available with both
JP_USB1 and JP_USB2
if an existing system
board has USB Type-B.
Figure 6. An example of the connection of the EVK supplying power to an existing system board
JP_USBD2
JP_USBD1
P N P N
VS NK
VB RD Y
PCB0214 Rev. A
G ND
SoC
USB
Peripheral
GND
VBUS
GPIOs
D-
D+
GPIOn
An example of the
existing system board
Primary Power Rail
USB-B
Port
Short the terminals P each other and the terminal N each
other to support flipped case on the Type-C connection.
VBRDY can use for the start
timing of USB communication.
5V POL
Connects the VBUS on the
USB-B port from a 5V POL
Figure 7. An example of USB connection on an existing system board
Type-C Cable
Type-C Wall
Charger
A
no
ny
m
o
us
U
S
B
P
o
w
e
r
D
e
liv
e
ry
A
n
a
ly
z
e
r
USB PD Protocol
Analyzer
BD93E11GWL-EVK-001