CALCulate<Chn>:EYE:INPut:LENGth:BITS
<BitLength>
Defines the length of a user-defined bit stream to be simulated for the related eye dia-
gram. The user-defined bit pattern (the default "10" or loaded from file, see
) is repeated until the specified length is reached.
This command will raise an execution error if the active trace in the selected channel is
not an eye diagram.
Before executing this command, the pattern type must be set to USER (see
CALCulate<Chn>:EYE:INPut:BPATtern:TYPE
).
Suffix:
<Chn>
.
Channel number used to identify the active trace
Parameters:
<BitLength>
Stream length, specified with units BITS, KIBITS (2^10 BITS),
MIBITS (2^20 BITS), or GIBITS (2^30 BITS)
Default unit: BITS
Options:
R&S
ZNB/ZNBT-K20
Manual operation:
See
CALCulate<Chn>:EYE:INPut:LENGth:PRBS
<PrbsLength>
Defines the length of the pseudo-random binary sequence to be simulated for the rela-
ted eye diagram.
This command will raise an execution error if the active trace in the selected channel is
not an eye diagram.
Before executing this command the pattern type must be set to PRBS (see
CALCulate<Chn>:EYE:INPut:BPATtern:TYPE
).
Suffix:
<Chn>
.
Channel number used to identify the active trace
Parameters:
<PrbsLength>
L5 | L7 | L9 | L10 | L11 | L13 | L15
L
i
represents an actual sequence length of 2
i
- 1.
Options:
R&S
ZNB/ZNBT-K20
Manual operation:
See
CALCulate<Chn>:EYE:INPut:OLEVel
<OneLevel>
CALCulate<Chn>:EYE:INPut:ZLEVel
<ZeroLevel>
Defines the highest/lowest (nominal) voltage level of the simulated digital signal gener-
ating the related eye diagram.
This command will raise an execution error if the active trace in the selected channel is
not an eye diagram.