GUI Reference
R&S
®
ZNB/ZNBT
237
User Manual 1173.9163.02 ─ 38
Segmented sweeps
In segmented frequency sweeps, the filter settings can be selected independently for
each segment. see
Chapter 5.3.2.2, "Define Segments Dialog"
Bandwidth
Sets the measurement bandwidth of the IF filter. Within the value range, the entered
value is rounded up to 1.5 * 10
n
Hz, 2 * 10
n
Hz, 3 * 10
n
Hz, 5 * 10
n
Hz, 7 * 10
n
Hz, 10 *
10
n
Hz. Values exceeding the maximum bandwidth are rounded down.
The regular bandwidth range is 1 Hz to 1 MHz. Option R&S
ZNB-K17/R&S
ZNBT-K17
enables bandwidths up to 10 MHz (see
Chapter 4.7.4, "Receiver Bandwidth 10 MHz"
Remote command:
[SENSe<Ch>:]BANDwidth[:RESolution]
[SENSe<Ch>:]BWIDth[:RESolution]
Selectivity
Selects the shape of the IF filter:
●
Filters with "Normal" selectivity provide the shortest settling time (recommended for
fast measurements).
●
"Medium" selectivity filters have steeper edges but require longer settling times.
●
"High"selectivity filters have the steepest edges and the longest settling times. This
filter type is suitable for isolating adjacent signals which are separated by a small
frequency spacing.
Remote command:
[SENSe<Ch>:]BANDwidth[:RESolution]:SELect
[SENSe<Ch>:]BWIDth[:RESolution]:SELect
Power Bw Avg Softtool