Configuring the internal baseband source
R&S
®
SMM100A
213
User Manual 1179.1341.02 ─ 05
"Unchanged"
Each segment is output with the clock rate defined in its waveform
file.
Note:
Segments with equal clock rates are required for "Next Seg-
ment Mode > Next Segment Seamless".
"Highest"
All segments are output at the highest available clock rate.
Note:
Trade-off between fast switch over and computing time. This
mode provides short switch over times between segments.
However, the computing time increases because the individual seg-
ments are resampled.
"User"
All segments are output at the clock rate defined by the parameter
"User Clock".
This mode is a trade-off between fast switch over and computing
time, too.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:CLOCk:MODE
User Clock Rate
Defines the sample rate used for multi-segment waveform output, if "Clock Mode >
User" is selected.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:CLOCk
Segment Marker
Defines the way the marker information within the separate segments is processed,
see also
Chapter 4.9.2.4, "Impact of the marker settings"
"Ignore"
The marker information carried in the individual segment waveform
files is not considered.
"Take Over"
The output waveform file contains the marker information as config-
ured in the individual waveform files.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:MARKer:MODE
Sequence Restart
Enables/disables the generation of an extra restart marker in the output waveform file.
If additional marker generation is enabled, the existing marker signals in the individual
segment waveform files are not considered, see also
Chapter 4.9.2.4, "Impact of the
"Disable"
No additional marker is generated.
"Marker 1, 2, 3"
Generates a restart marker signal at the beginning of the first seg-
ment of the complete multi-segment sequence.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:MARKer:FSEGment
Generating multi-segment waveform files