Remote Control Commands
R&S
®
SMF100A
473
Operating Manual 1167.2319.02 ─ 12
Parameters:
<Offset>
float
Increment: 0.01
*RST:
0
Example:
FREQ:OFFS 500kHz
sets the frequency offset to 500 kHz.
Manual operation:
See
[:SOURce<hw>]:FREQuency:PLL:MODE
<Mode>
Sets the bandwidth of the main PLL (Phase Locked Loop).
Parameters:
<Mode>
NORMal | NARRow
*RST:
NORMal
Manual operation:
See
[:SOURce<hw>]:FREQuency:SPAN
<Span>
Determines the extent of the frequency sweep range. This setting in combination with
the center frequency setting (
[:SOURce<hw>]:FREQuency:CENTer
) defines the
sweep range.
This parameter is related to the start and stop frequencies. If you change the fre-
quency, the span changes accordingly.
f
SPAN
= f
STOP
- f
STARt
f
STARt
> f
STOP
is permitted.
Parameters:
<Span>
float
Range:
full frequency range
Increment: see the data sheet: RF characteristics > Resolution
of setting
*RST:
400E6
Example:
FREQ:CENT 400 MHz
sets the center frequency of the frequency sweep to 400 MHz.
FREQ:SPAN 200 MHz
sets a span of 200 MHz. This sets the sweep range to 300 MHz
to 500 MHz.
Manual operation:
See
[:SOURce<hw>]:FREQuency:STARt
<Start>
Sets the start frequency for the RF sweep.
SOURce Subsystem