:OUTPut:BLANk:WIDTh
<Width>
The command selects the width of the blank marker.
Parameters:
<Width>
RFBLank | TRIGrf
RFBLanking
The blank marker starts after the external sweep trigger signal.
TRIGrf
The blank marker starts already with the external sweep trigger
signal.
*RST:
RFBLank
Example:
OUTP:BLAN:MODE RFBL
The blank marker starts after the trigger signal.
Manual operation:
See
:OUTPut:FPRoportional:SCALe
<Scale>
The command selects the V/GHz ratio for the output.
Parameters:
<Scale>
S0V5 | S1V0
*RST:
S1V0
Example:
OUTP:FPR:SCAL S0V5
Sets the V/GHz ratio for the output to 0.5.
Manual operation:
See
:OUTPut<hw>[:STATe]
<State>
Activates and deactivates the RF output signal (RF ON / RF OFF).
Parameters:
<State>
0 | 1 | OFF | ON
*RST:
0
Example:
OUTP OFF
deactivates the RF output.
Manual operation:
See
:OUTPut<hw>[:STATe]:PON
<Pon>
Selects the state of the RF output when the instrument is switched on.
OUTPut Subsystem