Instrument Function
R&S
®
SMF100A
289
Operating Manual 1167.2319.02 ─ 12
State - LF Level Sweep
Activates the LF level sweep signal generation.
Note:
Activating a sweep mode automatically deactivates other sweeps and the list mode.
Remote command:
[:SOURce]:LFOutput:VOLTage:MODE
Mode - LF Level Sweep
Selects the sweep instrument operating mode and sweep mode.
If you change the sweep mode during the execution, the signal generator stops the
sweep and starts with the next trigger event at the initial value.
The "Reset Sweep" button sets the sweep to the start value.
"Auto"
Sets an automatic repeated sweep cycle.
Example:
SOUR:LFO:SWE:VOLT:MODE AUTO
TRIG:LFVS:SOUR AUTO
SOUR:LFO:VOLT:MODE SWE