Instrument Function
R&S
®
SMF100A
278
Operating Manual 1167.2319.02 ─ 12
Remote command:
[:SOURce<hw>]:NOISe:LEVel:RELative?
Noise Level - Noise
Indicates the level of the noise signal per Hz in the total bandwidth.
Remote command:
[:SOURce<hw>]:NOISe:LEVel[:ABSolute]?
5.6.1.3
LF Frequency Sweep
The "LF Frequency Sweep" dialog is used to configure and activate an LF frequency
sweep signal.
To open the dialog, select "LF Gen./Noise > Configure > LF Frequency Sweep" or use
the MENU key under "LF Gen./Noise".
The LF sweep mode is activated and the sweep mode is selected. The buttons are
used to reset the LF sweep (all sweep modes) or to execute the LF sweep ("Single"
mode).
The sweep range, sweep spacing and dwell time are set in the bottom of the section.
Additionally, you can set the trigger slope.
State
Activates the LF frequency sweep signal generation.
Note:
Activating a sweep mode automatically deactivates other sweeps and the list mode.
Remote command:
[:SOURce<hw>]:LFOutput:FREQuency:MODE