DVB-S2 Configuration and Settings
R&S
®
SMCVB-K168
20
User Manual 1179.1064.02 ─ 03
Measured Data Rate ← Input Stream <num> table
Requires "Source > External".
Displays the measured value of the data rate r
meas
of one of the following:
●
External transport stream including null packets input at "User 1" connector
●
External transport stream including null packets input at "IP Data/LAN" connector
(TSoverIP)
The value r
meas
equals the sum of useful data rate r
useful
and the rate of null packets r
0
:
If "Stuffing > Off", ensure that the measured data rate equals the maximum useful data
rate (r
meas
= r
max. useful
).
Remote command:
[:SOURce<hw>]:BB:DVBS2[:INPut][:IS<ch>]:DATarate?
Useful Data Rate ← Input Stream <num> table
Requires "Source > External/TS Player".
Displays the data rate of useful data r
useful
of the external transport stream. The data
rate is measured at the input of the installed input interface.
Remote command:
[:SOURce<hw>]:BB:DVBS2[:IS<ch>]:USEFul[:RaTE]
3.2.3
Test Signal Settings
Access:
► Select "Input Signal > Test Signal".
The tab provides settings necessary to configure the input test signal.
Input Signal Settings