![Rohde & Schwarz SMBV100A Скачать руководство пользователя страница 860](http://html1.mh-extra.com/html/rohde-and-schwarz/smbv100a/smbv100a_operating-manual_1477735860.webp)
Remote Control Commands
R&S
®
SMBV100A
845
Operating Manual 1176.8016.02 ─ 17
Example:
SWE:FREQ:MODE AUTO
sets the triggered sweep mode, i.e. a trigger is required to start
the sweep.
TRIG:FSW:SOUR SING
sets the "Single" trigger mode, i.e. a trigger starts a single
sweep.
TRIG:FSW
starts a single RF frequency sweep.
Usage:
Event
Manual operation:
See
" Execute Single Sweep - Frequency Sweep "
:TRIGger<hw>:LFFSweep
Usage:
Event
Manual operation:
See
Immediately starts an LF frequency sweep.
The command is effective in sweep mode "Single" (
LFO:SWE:MODE AUTO
in combina-
tion with
TRIG:LFFS:SOUR SING
).
:TRIGger<hw>:LFFSweep:SOURce
<Source>
Sets the trigger source for the LF sweep. The trigger is triggered by the com-
mand
:SOURce:LFOutput:SWEep[:FREQuency]EXECute
.
The names of the parameters correspond directly to the various settings under manual
control. SCPI uses other names for the parameters; these names are also accepted by
the instrument. The SCPI names should be used if compatibility is an important consid-
eration.
An overview of the various names is given in the
TRIGger Subsystem