![Rohde & Schwarz SMBV100A Скачать руководство пользователя страница 766](http://html1.mh-extra.com/html/rohde-and-schwarz/smbv100a/smbv100a_operating-manual_1477735766.webp)
Remote Control Commands
R&S
®
SMBV100A
751
Operating Manual 1176.8016.02 ─ 17
Parameters:
<State>
0 | 1 | OFF | ON
*RST:
1
Example:
IQ:OUTP:ANAL:BIAS:OPT:STAT ON
activates optimization for RF output.
Manual operation:
See
"Optimize I/Q Signals for RF Output"
[:SOURce<hw>]:IQ:OUTPut:LEVel
<Level>
Sets the off-load voltage.
Single ended Output:
●
Value range: 1 mV ... 1.5 V EMF.
Differential Output:
●
Value range: 2 mV ... 3 V EMF.
Parameters:
<Level>
float
Range:
0.02 to 4
Increment: 0.001
*RST:
1
Default unit: V
Example:
SOURce1:IQ:OUTPut:LEVel 2
sets a off-load level of 2 V
Manual operation:
See
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:POWer:PEP:RESult?
Displays the resulting output off-load voltage of both signal components at the rear
panel.
Return values:
<Result>
float
Range:
0.02 to 4
Increment: 0.001
*RST:
1
Usage:
Query only
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:MODE
<Mode>
Selects the mode for setting the outputs.
Selection
FIXed
locks all
IQ:OUTPut
-commands except for
IQ:OUTPut:TYPE
and
sets them to predefined values (
*RST
).
SOURce Subsystem