![Rohde & Schwarz SMBV100A Скачать руководство пользователя страница 707](http://html1.mh-extra.com/html/rohde-and-schwarz/smbv100a/smbv100a_operating-manual_1477735707.webp)
Remote Control Commands
R&S
®
SMBV100A
692
Operating Manual 1176.8016.02 ─ 17
[:SOURce<hw>]:BB:IMPairment:STATe
<State>
The command activates (ON) and deactivates (OFF) the three impairment or correc-
tion values LEAKage, QUADrature and IQRatio for the digital baseband signal prior to
input into the I/Q modulator.
Parameters:
<State>
0 | 1 | OFF | ON
*RST:
0
Example:
BB:IMP:STAT OFF
deactivates digital impairment.
Manual operation:
See
[:SOURce<hw>]:BB:IMPairment:OPTimization:MODE
<Mode>
This command sets the optimization mode.
Parameters:
<Mode>
FAST | QHIGh
FAST
Optimization is reached by compensation for I/Q skew.
QHIGh
Optimization is reached by compensation for I/Q skew and fre-
quency response correction.
*RST:
FAST
Example:
BB:IMP:OPT:MODE FAST
sets the optimization mode Fast.
Manual operation:
See
"Optimization Mode - Digital Impairments"
[:SOURce<hw>]:BB:IMPairment:OPTimization:STATe
<State>
Activates and deactivates internal compensation of signal distortions by the I/Q modu-
lator.
Parameters:
<State>
0 | 1 | OFF | ON
*RST:
1
Example:
BB:IMP:OPT:STAT ON
activates internal compensation of signal distortions.
Manual operation:
See
"Optimize internal IQ-Impairments for RF Output - Digital
7.16.3.6
SOURce:BB:MCCW Subsystem
This subsystem contains the commands for setting the Multi Carrier CW signals.