![Rohde & Schwarz SMBV100A Скачать руководство пользователя страница 431](http://html1.mh-extra.com/html/rohde-and-schwarz/smbv100a/smbv100a_operating-manual_1477735431.webp)
Instrument Function
R&S
®
SMBV100A
416
Operating Manual 1176.8016.02 ─ 17
Remote command:
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:LEVel[:MODE]
Clock
Selects the clock rate mode for the multi segment waveform.
"Unchanged"
A segment is output with the clock rate defined in the file.
If segments have different clock rates, extended trigger mode "Next
Segment" allows internal segment switchovers only ("Internal" trigger
source).
Extended trigger mode "Next Segment Seamless" can only be
selected if all segments have the same clock rate.
"Highest"
All segments are output at the highest available clock rate.
This mode provides very short switchover times between segments.
The time for calculating the multi segment waveform is increased
since the individual segments have to be resampled.
"User"
All segments are output at the clock rate defined in "User Clock".
This mode provides very short switchover times between segments.
The time for calculating the multi segment waveform is increased
since the individual segments have to be resampled.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:CLOCk:MODE
User Clock Rate
Defines the sample rate used for multi segment waveform output in case of Clock
Mode "User".
Remote command:
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:CLOCk
Segment Marker
Defines the way the marker information within the separate segments is processed.
"Ignore"
The marker information carried in the individual segment waveform
files is not considered.
"Take Over"
The output waveform file contains the marker information as config-
ured in the individual waveform files.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:MARKer:MODE
Sequence Restart
Enables/disables the generation of an additional marker restart signal in the output
waveform file.
If additional marker generation is enabled, the existing marker signals in the individual
segment waveform files are not considered.
"Disable"
No additional marker is generated.