![Rohde & Schwarz SMBV100A Скачать руководство пользователя страница 405](http://html1.mh-extra.com/html/rohde-and-schwarz/smbv100a/smbv100a_operating-manual_1477735405.webp)
Instrument Function
R&S
®
SMBV100A
390
Operating Manual 1176.8016.02 ─ 17
The buttons in the last section lead to submenu for general trigger, clock and mapping
settings.
Trigger In
The "Trigger In" section is where the trigger for the signal is set. Various parameters
will be provided for the settings, depending on which trigger source - internal or exter-
nal - is selected. The current status of signal generation ("Running" or "Stopped") is
indicated for all trigger modes.
Trigger Mode
Selects trigger mode.
The trigger mode determines the effect of a trigger on the signal generation.
"Auto"
The signal is generated continuously.
"Retrigger"
The signal is generated continuously. A trigger event (internal or
external) causes a restart.
"Armed_Auto"
The signal is generated only when a trigger event occurs. Then the
signal is generated continuously.
Button "Arm" stops signal generation. A subsequent trigger event
(internal with "Execute Trigger" or external) causes a restart.
"Armed_Ret-
rigger"
The signal is generated only when a trigger event occurs. Then the
signal is generated continuously. Every subsequent trigger event cau-
ses a restart.
Button "Arm" stops signal generation. A subsequent trigger event
(internal with "Execute Trigger" or external) causes a restart.
"Single"
The signal is generated only when a trigger event occurs. Then the
signal is generated once to the length specified at "Signal Duration".
Every subsequent trigger event (internal with "Execute Trigger" or
external) causes a restart.
Remote command:
[:SOURce<hw>]:BB:ARBitrary[:TRIGger]:SEQuence
Signal Duration Unit
Defines the unit for the entry of the length of the signal sequence to be output in the
"Single" trigger mode.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:TRIGger:SLUNit