Setting a sweep
A sweep is set in five basic steps which are shown below taking a frequency sweep as
an example.
1. Set the sweep range ("Start Freq" and "Stop Freq" or "Center Freq" and "Span").
2. Select linear or logarithmic sweep spacing ("Spacing").
3. Set the step width ("Step Lin/Log") and dwell time ("Dwell Time").
4. Activate the sweep ("Mode" to Auto, Single, Step or Extern Single, Extern Step).
5. Trigger the sweep, except for Auto mode ("Execute Single Sweep", Current Fre-
quency or External Trigger Signal).
It is recommended to switch off the display update for optimum sweep performance
especially with short dwell times (see
Chapter 5.2.3.7, "Display Update"
5.5.14.2
RF Frequency Sweep
The dialog enables you to activate and configure a sweep for the RF frequency.
To open the "RF Frequency Sweep" dialog, select "RF/A Mod > Configure > RF Fre-
quency Sweep" or use the MENU key under "RF/A Mod".
In the top section of the dialog, the RF sweep is activated and the sweep mode is
selected.
The buttons are used to reset the RF sweep (all sweep modes) or to execute the RF
sweep ("Single" mode).
The sweep range, sweep spacing and dwell time are set in the bottom section.
You can configure the sweep range of the RF sweep in two ways, either by entering
the "Start" and "Stop" values or by entering the "Center" frequency and the "Span".
The two sets of parameters correlate as follows:
●
"Start Freq" = "Center Freq" - "Span"/2
●
"Stop Freq" = "Center Freq" + "Span"/2
●
"Center Freq" = ("Start Freq" + STOP FREQ)/2
●
"Span" = "Stop Freq" - "Start Freq"