Remote Control Commands
R&S
®
SMBV100A
598
Operating Manual 1407.6062.32 ─ 08
Example:
BB:MCCW:EDIT:CARR:POW -50 dB
sets the power of the carrier to -50 dB.
[:SOURce<hw>]:BB:MCCW:EDIT:CARRier:STARt
<Start>
The command selects the first carrier in the carrier range to which the settings with
the
:BB:MCCW:EDIT:CARR:...
commands shall apply.
Parameters:
<Start>
integer
Range:
0 to 8191
Increment: 1
*RST:
0
Example:
BB:MCCW:EDIT:CARR:STAR 4
the carrier range starts at carrier 4.
[:SOURce<hw>]:BB:MCCW:EDIT:CARRier:STATe
<State>
The command switches all the carriers in the selected carrier range on or off.
Parameters:
<State>
0 | 1 | OFF | ON
*RST:
1
Example:
BB:MCCW:EDIT:CARR:STAT ON
sets all the carriers in the carrier range to ON.
[:SOURce<hw>]:BB:MCCW:EDIT:CARRier:STOP
<Stop>
The command selects the last carrier in the carrier range to which the settings with
the
:BB:MCCW:EDIT:CARR:...
commands shall apply.
Parameters:
<Stop>
integer
Range:
0 to 8191
Increment: 1
*RST:
0
Example:
BB:MCCW:EDIT:CARR:STOP 40
the carrier range stops at carrier 40.
Trigger Settings
The trigger settings are available for R&S SMx and R&S AMU instruments only.
EXTernal<ch>
SOURce Subsystem