Operating the Instrument
R&S
®
RTM2000
42
Getting Started 1317.4710.02 ─ 0101
1 = Information bar
2 = Waveform labels
3 = Waveform window
4 = Information bar of the Zoom window
5 = Zoom window
6 = Results table
7 = Menu
8 = Trigger position
Information bar
The upper part of the display shows the information bar with main settings:
1 = Time base (horizontal scale)
2 = Trigger offset (horizontal position)
3 = Trigger mode
4 = Trigger settings: Trigger source, trigger type settings (for Edge trigger: level, slope, coupling, filter)
5 = Sample rate
6 = Acquisition mode
7 = Acquisition state
Zoom and FFT windows have their specific information bars which are described in the
correspondent chapters in the "User Manual".
Waveform labels
The labels for channel, math and reference waveforms show the vertical scale value
and the coupling. The label of the selected waveform is highlighted with the waveform
color.
Windows
The main window shows one or more waveforms: channel waveforms, reference and
math waveforms. The grid marks the vertical und horizontal divisions. If zoom, FFT or
XY-view is selected, the display shows two or more windows. The zoom, FFT or XY-
trace appear in the large main window. The basic waveforms are shown in smaller win-
dows for overview.
Results table
Results of automatic and cursor measurements are shown in the results table. Results
of configured measurements appear in the two left columns. Cursor and Quick Meas
results are shown in the three columns on the right.
Menu
Shows the current functions of the softkeys.
Trigger position
The trigger position marker and the trigger level marker have the color of the trigger
source waveform.
Understanding Display Information