background image

R&S®RT-ZC02

 

R&S®RT-ZC03

AC/DC Current Probe

 

User Manual

/ U

ser

 M

anual

Содержание RT-ZC02

Страница 1: ...R S RT ZC02 R S RT ZC03 AC DC Current Probe User Manual User Manual...

Страница 2: ...ecifications RT ZC03 6 Specifications RT ZC02 7 4 Operating Instructions RT ZC03 8 9 12 12 12 12 12 13 Operating Instructions RT ZC02 4 1 Switch On 4 2 Zero Adjustment 4 3 Current Measurement 4 4 Auto...

Страница 3: ...has been designed for use with DMMs only Using advanced Hall Effect technology the i30s can accurately measure currents with a resolution of 1 mA from 5 mA to 30 A over the frequency range of DC to 1...

Страница 4: ...hold the Current Probe anywhere beyond the tactile indicator Before each use inspect the Current Probe Look for cracks or missing portions of the Current Probe housing or output cable insulation Also...

Страница 5: ...WEEE compliant This product is designed to be safe under the following con ditions indoor use altitude up to 2000m temperature 0 C to 50 C maximum relative humidity 80 for temperatures up to 31 C decr...

Страница 6: ...C typ Output sensitivity 100m V A Frequency range DC to 100 kHz 0 5 dB typ Max slew rate 20 A s typ Response time better than 1 s Working voltage 300 VRMS AC or DC General data Operating temperature 0...

Страница 7: ...10 VRMS typ Gain variation 0 15 of reading C typ Output sensitivity 10 1 mV A Frequency range DC to 20 kHz 3 dB typ Max slew rate 20 A s typ Response time better than 5 s Working voltage 300 VRMS AC...

Страница 8: ...without notice 4 Operating Instructions RT ZC03 1 2 5 4 7 9 8 6 4 3 1 Jaws 2 Conventional current direction 3 Tactile Barrier 4 Battery cover 5 Battery cover screw 6 Jaw trigger 7 ON OFF switch 8 Aut...

Страница 9: ...hout notice Operating Instructions RT ZC02 1 Jaws 2 Conventional current direction 3 Tactile Barrier 4 Battery cover 5 Battery cover screw 6 Jaw trigger 7 ON OFF and range switch 8 Auto zero button 9...

Страница 10: ...10 Subject to change without notice Typical performance Plots RT ZC03 20 15 10 5 0 10 100 1000 10000 100000 Frequency Hz Phase Shift in Degrees Relative Gain in db...

Страница 11: ...1000A Gain dB 100A CP1005 Phase Response 45 00 40 00 35 00 30 00 25 00 20 00 15 00 10 00 5 00 0 00 10 100 1000 10000 100000 Frequency Hz Phase Shift in Degrees phase 100A phase 1000A 5 Warning To avo...

Страница 12: ...ctor en suring a good contact between the closing faces of the jaws Observe and take measurements as required Positive output indicates that the current flow is in the direction shown by the arrow on...

Страница 13: ...arantee compliance with the specified technical data The testing is performed with testing equipment that is calibrated to national standards The statutory warranty provisions shall be governed by the...

Страница 14: ...rohde schwarz com Service www service rohde schwarz com Subject to change Data without tolerance limits is not binding R S is a registered trademark of Rohde Schwarz GmbH Co KG Trade names are tradema...