Instrument Functions
R&S
®
UPP
319
User Manual 1411.1055.32 ─ 10
"Intern"
The internal generator is selected as the input. A loop measurement
can be performed without a connected cable being required (loop-
back test).
Remote command:
Format
Selection of the I
2
S analyzer format
"Standard I
2
S"
The I
2
S analyzer receives in the standard I
2
S format. The following
parameters that have an effect on the format have fixed default set-
tings:
First Bit = MSB
Fsync Slope .... Left(1) = Falling
Word Offset .... -1
"User-defina-
ble"
The I
2
S analyzer receives in a format similar to I
2
S.
The following format-influencing parameters are additionally availa-
ble:
First Bit
Fsync Slope
Word Offset
Remote command:
First Bit
Used to define the data bit receiving sequence
"MSB"
The most significant data bit is received first.
"LSB"
The least significant data bit is received first.
Remote command:
Fsync Slope
Polarity of the Fsync signal.
"Rising"
With a word offset of 0 a rising signal edge indicates the word begin-
ning of the left data word (channel 1).
"Falling"
With a word offset of 0 a falling signal edge indicates the word begin-
ning of the left data word (channel 1).
Remote command:
Configuring the I
2
S Analyzer
Содержание R&S UPP
Страница 1: ...R S UPP Audio Analyzer User Manual User Manual Version 10 1411105532 ÅP ...
Страница 34: ...Contents R S UPP 18 User Manual 1411 1055 32 10 ...
Страница 630: ...Instrument Functions R S UPP 614 User Manual 1411 1055 32 10 Format ...
Страница 631: ...Instrument Functions R S UPP 615 User Manual 1411 1055 32 10 Format ...