Remote Control Commands
R&S
®
RTM3000
625
User Manual 1335.9090.02 ─ 08
BUS<b>:UART:PARity
<Parity>
Defines the optional parity bit that is used for error detection.
Suffix:
<b>
.
1..2
Selects the bus.
Note: SPI and UART protocols occupy two bus lines.
Parameters:
<Parity>
ODD | EVEN | NONE
*RST:
NONE
BUS<b>:UART:SBIT
<StopBitNumber>
Sets the stop bits.
Suffix:
<b>
.
1..2
Selects the bus.
Note: SPI and UART protocols occupy two bus lines.
Parameters:
<StopBitNumber>
B1 | B1_5 | B2
1 stop bit, 1.5 stop bits or 2 stop bits are possible.
*RST:
B1
BUS<b>:UART:BAUDrate
<Baudrate>
Sets the number of transmitted bits per second.
Suffix:
<b>
.
1..4
Parameters:
<Baudrate>
Range:
100 to 78.1E6
Increment: 100
*RST:
115200
Default unit: Bit
BUS<b>:UART:BITime
<BurstIdleTime>
Sets the minimal time between two data frames (packets), that is, between the last
stop bit and the start bit of the next frame.
Suffix:
<b>
.
1..4
Parameters:
<BurstIdleTime>
Range:
Range depends on the bus configuration, mainly on
bit rate and symbol size.
Default unit: s
Serial Bus Analysis