Remote Control Commands
R&S
®
RTM3000
559
User Manual 1335.9090.02 ─ 08
.............................................................................................. 560
............................................................................................. 560
................................................................................................560
BPLot:GAIN:DATA?
Returns the data of the gain waveform.
Parameters:
<GainData>
Usage:
Query only
BPLot:GAIN:ENABle
Enables the gain waveform for the Bode plot.
Parameters:
<Enable>
ON | OFF
*RST:
ON
BPLot:GAIN:POSition
Sets the vertical position of the gain waveform in divisions.
Parameters:
<WaveformPosition> Range:
-20.0 to 20.0
Increment: 0.1
*RST:
3.0
BPLot:GAIN:SCALe
Sets the vertical scale for the gain waveform.
Parameters:
<WaveformScale>
Range:
0.1 to 20.0
Increment: 0.1
*RST:
20.0
BPLot:PHASe:DATA?
Returns the data of the phase waveform.
Parameters:
<PhaseData>
Usage:
Query only
BPLot:PHASe:ENABle?
Enables the phase waveform for the Bode plot.
Applications
www.allice.de
Allice Messtechnik GmbH