Remote Control Commands
R&S
®
RTM3000
451
User Manual 1335.9090.02 ─ 08
PDETect
Peak Detect: the minimum and the maximum of n samples in a
sample interval are recorded as waveform points.
HRESolution
High resolution: The average of n sample points is recorded as
waveform point.
*RST:
SAMPle
CHANnel<m>:ARIThmetics
<TrArith>
Selects the method to build the resulting waveform from several consecutive acquisi-
tions of the signal.
Suffix:
<m>
.
1..4
The command affects all channels regardless of the indicated
channel number. The suffix can be omitted.
Parameters:
<TrArith>
OFF | ENVelope | AVERage
OFF
The data of the current acquisition is recorded according to the
decimation settings.
ENVelope
Detects the minimum and maximum values in an sample interval
over a number of acquisitions.
AVERage
Calculates the average from the data of the current acquisition
and a number of acquisitions before. The number of used
acquisitions is set with
.
*RST:
OFF
ACQuire:PEAKdetect
<PeakDetect>
Enables or disables the peak detect acquisition mode.
You can use this command alternatively to
Parameters:
<PeakDetect>
AUTO | OFF
*RST:
OFF
ACQuire:HRESolution
<HighRes>
Enables or disables the high resolution acquisition mode.
You can use this command alternatively to
Waveform Setup
www.allice.de
Allice Messtechnik GmbH