Remote control commands
R&S
®
RTB2000
530
User Manual 1333.1611.02 ─ 11
LOGic<p>:PROBe[:ENABle]?
Checks if the logic probe is connected.
Suffix:
<p>
.
1..2
Selects the pod.
Return values:
<ProbeEnable>
1 | 0
1 = connected, 0 = not connected
Usage:
Query only
LOGic<p>:CURRent:STATe:MAXimum?
DIGital<m>:CURRent:STATe:MAXimum?
LOGic<p>:CURRent:STATe:MINimum?
DIGital<m>:CURRent:STATe:MINimum?
Both commands together return the current status of the indicated logic channel/pod
regardless of the trigger settings, and even without any acquisition.
xxx:CURR:STAT:MIN returns
xxx:CURR:STAT:MAX returns
Signal
0
0
Low
1
1
High
0
1
Toggle
Suffix:
<m>
.
0..15
Selects the logic channel
<p>
1..2
Selects the logic pod
Return values:
<CurrentState>
Range:
0 | 1
Usage:
Query only
15.12.1.2
Logic analyzer configuration
........................................................................................ 531
.................................................................................................531
....................................................................................... 532
Mixed signal option (option R&S
RTB-B1)