Operating Manual 1164.4556.12 - 06
6.153
R&S FSP
Remote Control – Description of Commands
SENSe Subsystem
[SENSe<1|2>:]CORRection:RECall
This command restores the instrument setting that was valid for the measurement of the reference
data, provided that the tracking generator is active.
Example:
"CORR:REC"
Characteristics:
*RST value: -
SCPI: conform
Mode:
A
This command is an event and therefore has no *RST value and no query.
This command is only valid in conjunction with the tracking generator / ext. generator control option
(B9/B10).
[SENSe<1|2>:]CORRection[:STATe]
ON | OFF
This command activates/deactivates the normalization of the measurement results in the selected
window provided that the tracking generator is active. The command is available only after acquisition
of a reference trace for the selected type of measurement (transmission/reflection, see command
[SENSe<1|2>:]CORRection:COLLect[:ACQire]
).
Example:
"CORR ON "
'Activates normalization in screen A.
Characteristics:
*RST value: OFF
SCPI: conform
Mode:
A
This command is only valid in conjunction with the tracking generator / ext. generator control option
(B9/B10).
[SENSe<1|2>:]CORRection:TRANsducer:ACTive?
This command queries the active transducer factor. If no transducer factor is active, an empty string is
returned.
Example:
"CORR:TRAN:ACT?"
Characteristics:
*RST value: -
SCPI: device-specific
Mode:
A
This command is a query and therefore has no *RST value.
[SENSe<1|2>:]CORRection:TRANsducer:ADJust:RLEVel[:STATe]
ON | OFF
This command switches the automatic adjustment of the reference level to the selected transducer
factor on or off. Prior to this command, the command
SENS:CORR:TRAN:SEL
must be sent.
Example:
"CORR:TRAN:SEL 'FACTOR1'"
"CORR"CORR:TRAN:ADJ:RLEV ON"
Characteristics:
*RST value: OFF
SCPI: device-specific
Mode:
A
Содержание R&S FSP Series
Страница 1: ...R S FSP Spectrum Analyzer Operating Manual 1164 4556 12 06 Test Measurement Operating Manual ...
Страница 24: ...R S FSP Putting into Operation 1 2 Operating Manual 1164 4556 12 06 ...
Страница 72: ...R S FSP Manual Operation 3 2 Operating Manual 1164 4556 12 06 ...
Страница 362: ...R S FSP Instrument Functions Trigger Port Option R S FSP B28 4 290 Operating Manual 1164 4556 12 06 ...
Страница 764: ...R S FSP Remote Control Programming Examples More Complex Programming Examples 7 30 Operating Manual 1164 4556 12 06 ...
Страница 793: ...R S FSP Index Operating Manual 1164 4556 12 06 4 11 ...
Страница 794: ...R S FSP 4 12 Operating Manual 1164 4556 12 06 ...
Страница 795: ...Operating Manual 1164 4556 12 06 4 13 R S FSP ...
Страница 796: ...R S FSP 4 14 Operating Manual 1164 4556 12 06 ...