CALCulate<1|2>:MARKer<1...4>:FUNCtion:NDBDown
<numeric_value>
This command defines the level spacing of the two delta markers to the right and left of marker 1 in the
selected measurement window. Marker 1 is always used as the reference marker. The numeric suffix
<1...4> is irrelevant for this command.
The temporary markers T1 and T2 are positioned by n dB below the active reference marker. The
frequency spacing of these markers can be queried with
CALCulate:MARKer:FUNCtion:
NDBDown:RESult
?.
If a negative value is entered than the markers are placed n dB above the active reference marker.
This is then a n dB up function which can be used for notch filter measurements:
Example:
"CALC:MARK:FUNC:NDBD 3dB"
'Sets the level spacing in screen A to 3 dB.
Characteristics:
*RST value: 6dB
SCPI: device-specific
Mode:
A
CALCulate<1|2>:MARKer<1...4>:FUNCtion:NDBDown:FREQuency?
This command queries the two frequencies of the N-dB-down marker in the selected measurement
window. The numeric suffix <1...4> is irrelevant for this command. The two frequency values are
separated by comma and output in ascending order.
A complete sweep with synchronization to sweep end must be performed between switching on the
function and querying the measured value to obtain a valid query result. This is only possible in single-
sweep mode.
Example:
"INIT:CONT OFF"
'Switches to single-sweep mode.
"CALC:MARK:FUNC:NDBD ON"
'Switches on the n-dB-down function in screen A.
"INIT;*WAI"
'Starts a sweep and waits for the end.
"CALC:MARK:FUNC:NDBD:FREQ?"
'Outputs the frequencies of the temporary markers in screen A.
Characteristics:
*RST value: -
SCPI: device-specific
Mode:
A
This command is only a query and therefore has no *RST value.
CALCulate<1|2>:MARKer<1...4>:FUNCtion:NDBDown:RESult?
This command queries the frequency spacing (bandwidth) of the N-dB-down markers in the selected
measurement window. The numeric suffix <1...4> is irrelevant for this command.
A complete sweep with synchronization to sweep end must be performed between switching on the
function and querying the measured value in order to obtain a valid query result. This is only possible
in single-sweep mode.
Содержание R&S FSP Series
Страница 1: ...R S FSP Spectrum Analyzer Operating Manual 1164 4556 12 06 Test Measurement Operating Manual ...
Страница 24: ...R S FSP Putting into Operation 1 2 Operating Manual 1164 4556 12 06 ...
Страница 72: ...R S FSP Manual Operation 3 2 Operating Manual 1164 4556 12 06 ...
Страница 362: ...R S FSP Instrument Functions Trigger Port Option R S FSP B28 4 290 Operating Manual 1164 4556 12 06 ...
Страница 764: ...R S FSP Remote Control Programming Examples More Complex Programming Examples 7 30 Operating Manual 1164 4556 12 06 ...
Страница 793: ...R S FSP Index Operating Manual 1164 4556 12 06 4 11 ...
Страница 794: ...R S FSP 4 12 Operating Manual 1164 4556 12 06 ...
Страница 795: ...Operating Manual 1164 4556 12 06 4 13 R S FSP ...
Страница 796: ...R S FSP 4 14 Operating Manual 1164 4556 12 06 ...