NB-IoT NPRACH Measurement
R&S
®
CMW-KM300/-KS300
382
User Manual 1178.5689.02 ─ 06
Usage:
Query only
Firmware/Software:
V3.7.20
4.5.3.19
Power Dynamics Results (Single Values)
The following commands return the statistical results of the power dynamics measure-
ment.
CALCulate:NIOT:MEAS<i>:PRACh:PDYNamics:CURRent?
CALCulate:NIOT:MEAS<i>:PRACh:PDYNamics:AVERage?
CALCulate:NIOT:MEAS<i>:PRACh:PDYNamics:MINimum?
CALCulate:NIOT:MEAS<i>:PRACh:PDYNamics:MAXimum?
FETCh:NIOT:MEAS<i>:PRACh:PDYNamics:CURRent?
FETCh:NIOT:MEAS<i>:PRACh:PDYNamics:AVERage?
FETCh:NIOT:MEAS<i>:PRACh:PDYNamics:MINimum?
FETCh:NIOT:MEAS<i>:PRACh:PDYNamics:MAXimum?
FETCh:NIOT:MEAS<i>:PRACh:PDYNamics:SDEViation?
READ:NIOT:MEAS<i>:PRACh:PDYNamics:CURRent?
READ:NIOT:MEAS<i>:PRACh:PDYNamics:AVERage?
READ:NIOT:MEAS<i>:PRACh:PDYNamics:MINimum?
READ:NIOT:MEAS<i>:PRACh:PDYNamics:MAXimum?
READ:NIOT:MEAS<i>:PRACh:PDYNamics:SDEViation?
Return the current, average, minimum, maximum and standard deviation single value
results of the power dynamics measurement.
The values described below are returned by
FETCh
and
READ
commands.
CALCulate
commands return limit check results instead, one value for each result listed below.
Return values:
<Reliability>
<OutOfTolerance>
Out of tolerance result, i.e. percentage of measurement inter-
vals of the statistic count for power dynamics measurements
exceeding the specified power dynamics limits.
Default unit: %
<OffPowerBefore>
OFF power before the preamble
Default unit: dBm
<OnPowerRMS>
ON power mean value
Default unit: dBm
<OnPowerPeak>
ON power peak value
Default unit: dBm
<OffPowerAfter>
OFF power after the preamble
Default unit: dBm
Example:
See
Performing Single-Shot Measurements
Usage:
Query only
Command Reference