NB-IoT NPRACH Measurement
R&S
®
CMW-KM300/-KS300
371
User Manual 1178.5689.02 ─ 06
CONFigure:NIOT:MEAS<i>:PRACh:LIMit:MERRor
<RMS>, <Peak>
Defines upper limits for the RMS and peak values of the magnitude error.
Parameters:
<RMS>
Range:
0 % to 100 %
*RST:
17.5 %, OFF
Default unit: %
Additional parameters: OFF | ON (disables the limit check | ena-
bles the limit check using the previous/default limit values)
<Peak>
Range:
0 % to 100 %
*RST:
35 %, OFF
Default unit: %
Additional parameters: OFF | ON (disables the limit check | ena-
bles the limit check using the previous/default limit values)
Example:
See
Firmware/Software:
V3.7.20
Manual operation:
See
CONFigure:NIOT:MEAS<i>:PRACh:LIMit:PERRor
<RMS>, <Peak>
Defines symmetric limits for the RMS and peak values of the phase error. The limit
check fails if the absolute value of the measured phase error exceeds the specified val-
ues.
Parameters:
<RMS>
Range:
0 deg to 180 deg
*RST:
17.5 deg, OFF
Default unit: deg
Additional parameters: OFF | ON (disables the limit check | ena-
bles the limit check using the previous/default limit values)
<Peak>
Range:
0 deg to 180 deg
*RST:
35 deg, OFF
Default unit: deg
Additional parameters: OFF | ON (disables the limit check | ena-
bles the limit check using the previous/default limit values)
Example:
See
Firmware/Software:
V3.7.20
Manual operation:
See
CONFigure:NIOT:MEAS<i>:PRACh:LIMit:FERRor
<FrequencyError>
Defines an upper limit for the carrier frequency error.
Command Reference
深圳德标仪器
135-1095-0799