NB-IoT Multi-Evaluation Measurement
R&S
®
CMW-KM300/-KS300
303
User Manual 1178.5689.02 ─ 06
<OBW>
Occupied bandwidth
Default unit: Hz
<TXpowerMin>
Minimum total TX power
Default unit: dBm
<TXpowerMax>
Maximum total TX power
Default unit: dBm
Example:
See
Usage:
Query only
Firmware/Software:
V3.5.10
FETCh:NIOT:MEAS<i>:MEValuation:SEMask:MARGin:ALL?
Returns spectrum emission mask margin results. A negative margin indicates that the
trace is located above the limit line, i.e. the limit is exceeded.
Results are provided for the current, average and maximum traces. For inactive areas,
NCAP is returned.
Return values:
<Reliability>
<OutOfTolerance>
Out of tolerance result, i.e. percentage of measurement inter-
vals of the statistic count for spectrum emission measurements
exceeding the specified spectrum emission mask limits.
Default unit: %
<MarginCurrNeg>
Comma-separated list of 12 margin results
For the current trace, area 1 to 12, negative frequency offsets
Default unit: dB
<MarginCurrPos>
Comma-separated list of 12 margin results
For the current trace, area 1 to 12, positive frequency offsets
Default unit: dB
<MarginAvgNeg>
Comma-separated list of 12 margin results
For the average trace, area 1 to 12, negative frequency offsets
Default unit: dB
<MarginAvgPos>
Comma-separated list of 12 margin results
For the average trace, area 1 to 12, positive frequency offsets
Default unit: dB
<MarginMinNeg>
Comma-separated list of 12 margin results
For the maximum trace, area 1 to 12, negative frequency offsets
Default unit: dB
<MarginMinPos>
Comma-separated list of 12 margin results
For the maximum trace, area 1 to 12, positive frequency offsets
Default unit: dB