NB-IoT Signaling
R&S
®
CMW-KM300/-KS300
164
User Manual 1178.5689.02 ─ 06
Firmware/Software:
V3.7.30
Options:
For DAPPlication: installed DAU
Manual operation:
See
CONFigure:NIOT:SIGN<i>:CONNection:TMODe
<Enable>
Specifies whether the UE is forced into a test mode. If enabled, the message "ACTI-
VATE TEST MODE" is sent to the UE.
Parameters:
<Enable>
OFF | ON
*RST:
ON
Example:
See
Configuring General Connection Settings
Firmware/Software:
V3.7.20
Manual operation:
See
"Use "Activate Testmode" Message"
CONFigure:NIOT:SIGN<i>:CONNection:TMODe:IPVersion
<IPversion>
Specifies which IP versions are allowed in test mode.
Parameters:
<IPversion>
IPV4 | IPV46
IPv4 only, IPv4/IPv6
*RST:
IPV4
Example:
See
Configuring General Connection Settings
Firmware/Software:
V3.7.20
Manual operation:
See
CONFigure:NIOT:SIGN<i>:CONNection:DAPPlication:CIOT
<Plane>
Selects the C-IoT optimization type to be used for the attach in data application mode.
Parameters:
<Plane>
CPL | UPL
Control plane or user plane C-IoT optimization
*RST:
CPL
Example:
See
Configuring General Connection Settings
Firmware/Software:
V3.7.30
Manual operation:
See
CONFigure:NIOT:SIGN<i>:CONNection:DAPPlication:IPVersion
<IPversion>
Specifies which IP versions are allowed in data application mode.
Command Reference
135-1095-0799