Remote Operation
R&S
®
OSP
242
User Manual 1178.7100.02 ─ 05
Figure 7-3: Most context functions are disabled during remote operation
Left = Switch unit is in local operation state
Right = Switch unit is in remote operation state
During remote operation, you
cannot execute
the following tasks in the user interface:
●
Operate any relays or output channels
●
Change any settings
●
Save or load any device backups or switching paths
But you
can monitor
the state of the system in the user interface:
●
Watch the states of all relays and I/O channels
●
Retrieve information on your frames, modules and paths
●
Use the functions
To terminate the remote operation mode and enable the user interface again, choose
one of the following actions:
●
In the remote control program, select "Disconnect" or "GTL" ("goto local") or an
equivalent command
●
In the local user interface, click "Context Menu" > "Goto Local Operation"
This button is available in the context menu of each
the switch unit is in remote operation state (GUI partly locked).
After returning to local operation, all functions of the switch unit are available locally in
its user interface.
When the switch unit receives the next RC command, it automatically returns to remote
operation state. Local operation is then locked, again.
LLO
Remote control programs like R&S
Forum can set the switch unit to a
"Local Lock-
out"
(LLO) state, which disables the "Goto Local Operation" button.
To terminate the LLO state, select GTR (goto remote) or GTL (goto local) in your
remote control program. See "Remote / Local Control" in