Remote Control Commands for Phase Noise Measurements
R&S
®
FSW-K40
138
User Manual 1173.9286.02 ─ 15
Example:
FETC:PNO:SWE:MDR?
would return, e.g.:
2.17,11.45,105.11,219.37,553.48
Usage:
Query only
Manual operation:
See
FETCh:PNOise:SWEep:SRATe?
This command queries the sampling rate used in each half decade.
Return values:
<SamplingRate>
Sampling rate as displayed in the Sweep Result List.
The command returns one value for each half decade as a
comma separated list.
Default unit: Hz
Example:
FETC:PNO:SWE:SRAT?
would return, e.g.:
25000,75000,250000,750000,2500000
Usage:
Query only
Manual operation:
See
FETCh:PNOise:SWEep:STARt?
This command queries the start frequency offset of each half decade.
Return values:
<Frequency>
Frequency offset as displayed in the Sweep Result List.
The command returns one value for each half decade as a
comma separated list.
Default unit: Hz
Example:
FETC:PNO:SWE:STAR?
would return, e.g.:
1000,3000,10000,30000,100000
Usage:
Query only
Manual operation:
See
FETCh:PNOise:SWEep:STOP?
This command queries the stop frequency offset of each half decade.
Return values:
<Measurements>
Frequency offset as displayed in the Sweep Result List.
The command returns one value for each half decade as a
comma separated list.
Default unit: Hz
Configure Numerical Result Displays