The Spectrum Application (RF Measurements)
R&S
®
FPL1000
318
User Manual 1178.3370.02 ─ 03
2. Select the "Load" button.
The settings from the selected file are restored to the R&S
FPL1000 and you can
repeat the SEM measurement with the stored settings.
How to save a user-defined SEM settings file
1. Configure the SEM measurement as required (see
form a Spectrum Emission Mask Measurement"
2. In the "Standard Files" tab of the "Spectrum Emission Mask" dialog box, define a
filename and storage location for the settings file.
3. Select the "Save" button.
The settings are stored to a file with the extension
.xml
as specified.
How to delete an SEM settings file
1. In the "Standard Files" tab of the "Spectrum Emission Mask" dialog box, select the
file you want to delete.
2. Select the "Delete" button.
3. Confirm the message.
The settings file is removed from the R&S
FPL1000.
How to restore default SEM settings files
The R&S
FPL1000 is delivered with predefined settings files which can be edited and
overwritten. However, you can restore the original files.
► In the "Standard Files" tab of the "Spectrum Emission Mask" dialog box, select the
"Restore Standard Files" button.
The original predefined settings files are available for selection on the
R&S
FPL1000.
How to Save SEM Result Files
The Result Summary from an SEM measurement can be saved to a file, which can be
exported to another application for further analysis, for example.
For details on the file format of the SEM export file, see
1. Configure and perform an SEM measurement as described in
"How to Perform a Spectrum Emission Mask Measurement"
2. In the "Overview" , select the "Analysis" button.
3. If necessary, change the "Decimal Separator" to "COMMA" for evaluation in other
languages.
4. Select the "Save" button.
Measurements and Results