Remote Control Commands
R&S
®
EX-IQ-BOX
332
User Manual 1409.5570.32 ─ 05
Manual operation:
See
[:SOURce<hw>]:EBOX:CPRI:TX|RX:TRIGger:ARM
Stops the current signal transmission. It continues either automatically or synchronized,
according to the used start condition.
Manual operation:
See
[:SOURce<hw>]:EBOX:CPRI:TX|RX:TRIGger:SOURce
<Trigger>
Defines the start condition for the scheduler, for data transmission and analysis.
Parameters:
<Trigger>
SOFTware | EXT1 | EXT2 | EXT3 | TXBF | TXHF | TXNF | RXBF |
RXHF | RXNF | SYNC
Manual operation:
See
[:SOURce<hw>]:EBOX:CPRI:SFRame<st>:DATA
<StaticFrameData>
Fills the complete CPRI frame with a static pattern for debugging purposes. This pattern
is transmitted as it is, without scaling, rounding or interleaving.
Parameters:
<StaticFrameData>
integer
Example:
[:SOURce<hw>]:EBOX:CPRI:SFRame<st>:DATA
"102010110000"
Manual operation:
See
[:SOURce<hw>]:EBOX:CPRI:TX:SIGNal<ch>:SOURce
<Source>
Determines the signal source for signal transmission to the DUT. That is, if you work in
the
RE Test Downlink
or the
REC Test Uplink
mode.
The signal comes either from an R&S instrument via the Digital I/Q Interface of the
R&S
EX-IQ-BOX, or the signal is generated internally or by means of the waveform
memory in the R&S
EX-IQ-BOX.
The R&S
EX-IQ-BOX converts the I/Q format of the signal into the CPRI protocol format.
Embedded with additional control information, the link transfers the data to the DUT.
CPRI Remote Control Commands