![Rohde & Schwarz EX-IQ-BOX Скачать руководство пользователя страница 332](http://html1.mh-extra.com/html/rohde-and-schwarz/ex-iq-box/ex-iq-box_user-manual_1477982332.webp)
Remote Control Commands
R&S
®
EX-IQ-BOX
317
User Manual 1409.5570.32 ─ 05
[:SOURce<hw>]:EBOX:CPRI:RECorder<ch>:ABORt
Stops and cancels the recording. You can abort the recording at any time and restart
again.
Example:
SOUR1:EBOX:CPRI:REC:ABOR
stops recording.
Usage:
Event
Manual operation:
See
[:SOURce<hw>]:EBOX:CPRI:RECorder<ch>:DATA:SOURce
<Source>
Selects the signal source of the signal to be recorded. All RX signals are available. In
order to record a signal, the signal must be selected in the respective RX dialog. Either
the uplink signal in CPRI RE test mode, or the downlink signal of the CPRI REC testmode
are possible. Assign the signal "DIG OUT 2 IQ / Recorder" or "Recorder" under
on page 331. Switch on signal
Parameters:
<Source>
string
String parameter to specify the I/Q data source of the signal to be
recorded.
Example:
SOUR1:EBOX:CPRI:REC:DATA:SOUR "signal_1"
select the signal_1 for recording.
Manual operation:
See
[:SOURce<hw>]:EBOX:CPRI:RECorder<ch>:DATA:SOURce:CATalog?
Returns a list of data sources, i.e. output signals in the current, or specified directory.
Return values:
<Srcs>
string
Example:
SOUR1:EBOX:CPRI:REC:DATA:SOUR:CAT?
read out all waveform files of the current directory.
Usage:
Query only
Manual operation:
See
[:SOURce<hw>]:EBOX:CPRI:RECorder<ch>:DATA:SRATe?
Queries the sample rate of the recorded signal.
Return values:
<Srate>
float
*RST:
3840000
Default unit: Hz