![Rohde & Schwarz EX-IQ-BOX Скачать руководство пользователя страница 329](http://html1.mh-extra.com/html/rohde-and-schwarz/ex-iq-box/ex-iq-box_user-manual_1477982329.webp)
Remote Control Commands
R&S
®
EX-IQ-BOX
314
User Manual 1409.5570.32 ─ 05
[:SOURce<hw>]:EBOX:CPRI:L1:RX:REMote:RAI?
Queries the RAI (
R
emote
A
rm
I
ndication) state at the DUT, i.e. if any remote part of the
end-to-end link has failed.
Return values:
<rai>
0 | 1 | OFF | ON
Example:
SOUR1:EBOX:CPRI:L1:RX:REM:RAI?
check if a remote part of the end-to-end link has failed.
Response:
0
if OK,
1
if not OK
Usage:
Query only
Manual operation:
See
[:SOURce<hw>]:EBOX:CPRI:L1:RX:REMote:RESet?
Queries whether the DUT is in reset state.
Return values:
<reset>
0 | 1 | OFF | ON
1
CPRI RE test mode: Confirms that a reset was performed.
CPRI REC test mode:
Confirms a reset request.
0
CPRI RE test mode:
No reset was performed.
CPRI REC test mode:
No reset is requested.
Example:
SOUR1:EBOX:CPRI:L1:RX:REM:RES?
check the reset state of the DUT.
Usage:
Query only
Manual operation:
See
[:SOURce<hw>]:EBOX:CPRI:L1:RX:REMote:SAP?
Queries whether the data communication failed (SDI
S
ervice Access Point
D
efect
I
ndi-
cation).
Return values:
<sap>
0 | 1 | OFF | ON
Example:
SOUR1:EBOX:CPRI:L1:RX:REM:SAP?
check the data communication.
Response:
1
(error)
data communication failed.
Usage:
Query only
Manual operation:
See
CPRI Remote Control Commands
Содержание EX-IQ-BOX