Parameters:
<Spolarity>
POSitive | NEGative
POSitive
Sets the strobe polarity to high level.
NEGative
Sets the strobe polarity to low level.
*RST:
POSitive
Example:
SOUR1:EBOX:USER:DATA:SPOL NEG
inverts of the strobe marker signal.
Manual operation:
See
[:SOURce]:BBIN:EXTernal:DATA:SPOSition
<Sposition>
[:SOURce<hw>]:IQ:OUTPut:EXTernal:DATA:SPOSition
<Sposition>
SOURce:TRANsmitter:DATA:SPOSition
<Sposition>
SOURce:RECeiver:DATA:SPOSition
<Sposition>
[:SOURce<hw>]:EBOX:USER:DATA:SPOSition
<Sposition>
Note:
This command refers to serial data transmission.
Sets the sample position of the strobe marker output. The strobe marker is output at the
UI_GP5 of the user interface.
Parameters:
<Sposition>
float
Range:
0 to word size-1
*RST:
0
Example:
SOUR1:EBOX:USER:DATA:SPOS 10
sets the strobe marker output to sample position 10.
Manual operation:
See
[:SOURce]:BBIN:EXTernal:DATA:STYPe
<Stype>
[:SOURce<hw>]:IQ:OUTPut:EXTernal:DATA:STYPe
<Stype>
SOURce:TRANsmitter:DATA:STYPe
<Stype>
SOURce:RECeiver:DATA:STYPe
<Stype>
[:SOURce<hw>]:EBOX:USER:DATA:STYPe
<Stype>
Selects the signal mode of the transmission. The digital I and Q signals are either trans-
mitted separately or the I and Q samples are assembled to a carrier signal and shifted to
an intermediate frequency (IF).
Note:
Currently the signal type is firmly set to "IQ" and read only. IQ transmits the digital
I and Q signal components separately.
Signal type "IF" is intended for future use.