
Remote Control Commands
R&S
®
EX-IQ-BOX
256
User Manual 1409.5570.32 ─ 05
Parameters:
<sav_rcl_state_number>
Determines to the specific <number> to be used with the
*RCL
command, e.g.
*RCL 4
.
<file_name>
String parameter to specify the file name with extension
*.savrcl
.
Setting parameters:
<State>
string
Example:
MMEM:STOR:STAT 4,"test.savrcl"
Usage:
Setting only
MMEMory:MDIRectory
<Mdirectory>
Creates a new subdirectory for mass memory storage in the specified directory. If no
directory is specified, a subdirectory is created in the default directory. This command
can also be used to create a directory tree.
Setting parameters:
<Mdirectory>
string
Example:
MMEM:MDIR "d:/test"
Usage:
Setting only
MMEMory:RDIRectory
<Rdirectory>
Removes an existing directory from the mass memory storage system. If no directory is
specified, the subdirectory with the specified name is deleted in the default directory.
Setting parameters:
<Rdirectory>
string
String parameter to specify the directory to be deleted.
Example:
MMEM:RDIR "d:/test"
Usage:
Setting only
MMEMory:STORe:STATe
<State>
Stores the current instrument setting in the specified file.
The instrument setting must first be stored in an internal memory with the same number
using the common command
*SAV
.
Parameters:
<sav_rcl_state_number>
Corresponds to the specific <number> defined with the
*SAV
command, e.g.
*SAV 4
.
<file_name>
String parameter to specify the file name with extension
*.savrcl
.
R&S EX-IQ-BOX - Remote Control Commands
Содержание EX-IQ-BOX
Страница 147: ...Protocol Settings R S EX IQ BOX 132 User Manual 1409 5570 32 05 CPRI...
Страница 391: ......